home *** CD-ROM | disk | FTP | other *** search
/ Libris Britannia 4 / science library(b).zip / science library(b) / PACKET / TAPR_116.ZIP / TAPR116K.DOC < prev   
Text File  |  1989-02-15  |  4KB  |  105 lines

  1. Note:
  2. If you are upgrading from 1.1.3 or older versions you will need to
  3. perform the 1.1.4 modification before using this release. Contact
  4. TAPR, P.O. Box 12925, Tucson AZ, 85732.  (602) 323-1710
  5. ***********************************************************************
  6.  
  7.                                                  November 7, 1988
  8.  
  9.  
  10.  
  11.                TNC-2 Software Release 1.1.6 Notes
  12.                ----------------------------------
  13.  
  14.  
  15. This  document  describes  the  differences  between  the  latest
  16. release  1.1.6 and the previous (1.1.5) release of TAPR  software
  17. for the TNC 2 Terminal Node Controller.
  18.  
  19. The reported checksum on powerup is $2E.
  20.  
  21. This release include "KISS" capability from K3MC.
  22.  
  23.  
  24.                           NEW COMMANDS
  25.                           ------------
  26.  
  27. KISS ON|OFF                                          default: OFF
  28.  
  29. This command is used to enter the "KISS" mode for operation  with
  30. various  experimental protocols.  KISS is used  with  intelligent
  31. host  computers.   The most popular use has been  in  conjunction
  32. with the KA9Q TCP/IP networking software, available from TAPR and
  33. elsewhere.
  34.  
  35. To  operate  KISS with this release, enter the command  KISS  ON,
  36. then the command RESTART (NOT RESET!).  The CON and STA LEDs will
  37. flash  three times when initially actiated.  This  command  will
  38. then  have effect for subsequent power on/off cycles.  To  return
  39. to normal operation, enter the command PARAM <device> 255 at the
  40.  
  41.       NET>
  42.  
  43. prompt  if you are running the KA9Q TCP/IP software package.   If
  44. you  cannot send this parameter with the software you  intend  to
  45. use,  you  must  power the TNC off,  then  disconnect  the  bbRAM
  46. battery for several minutes, then reconnect the battery and power
  47. up again.
  48.  
  49. NOTE:     While  the  TNC  is  in the  "KISS"  mode,  normal  TNC
  50.           operation is suspended and the familiar command set  is
  51.           inoperative.
  52.  
  53. TXUIFRAM ON|OFF                                      default: OFF
  54.  
  55. This  command  deterines  whether the  TNC  will  transmit  most
  56. unconnected information packets.
  57.  
  58. Setting  TXUIFRAMe  OFF  will  prevent  all  but  BEACON  and  ID
  59. unconnected ("UI") frames from being originated and  transmitted.
  60. This  is  most useful for BBS and other stations  which  tend  to
  61. leave  unacknowledged  data  in the TNC transmit  buffer  when  a
  62. connection is lost.  The normal behavior of a TNC would send  the
  63. buffered data as "UI" frames, adding to channel congestion.
  64.  
  65. The  behavior  with  TXUIframe  OFF  serves  to  reduce   channel
  66. congestion because the now useless data is never sent.
  67.  
  68. NOTE:     TXUIFRAM has NO effect on the digipeating of UI frames.
  69.           It  only  affects  frames  being  originated  at   this
  70.           station.
  71.  
  72.  
  73.  
  74.                              CHANGES
  75.                              -------
  76.  
  77.  
  78. o -  The  TNC  now requires that the Data  Carrier  Detect  (DCD)
  79.      signal  from  the  internal or external  modem  be  asserted
  80.      (true) for a packet to be received.  This change is intended
  81.      to  ensure  that a modem with a "threshold" control  is  set
  82.      properly.
  83.  
  84.      The  result  is that the station operator will set  the  DCD
  85.      control  in order to receive data.  This then  ensures  that
  86.      the TNC will have the best chance of detecting other station
  87.      activity,  reducing collisions that would  otherwise  result
  88.      from  jumping  on a channel believed to be open when  it  is
  89.      really in use by another station.
  90.  
  91.      This protection feature will be invisible to most operators.
  92.  
  93. NOTE:     To test with digital loopback, FULLDUP must be ON.  For
  94.           normal operation, FULLDUP should be set to OFF.
  95.  
  96.                  THE PACKET REVOLUTION REVOLVES!
  97.  
  98.  
  99.                       Howard Goldstein N2WX
  100.                       TNC-2 Software Design
  101.                                'n
  102.                          Damage Control
  103.  
  104.  
  105.